[. . . ] J6 The GE/CADDX NX-8e has built-in serial communication and does not require a NX584. Instead, use a ZCIF232 interface adaptor kit to provide a serial connection. (See connection diagram on page 1) We strongly recommend you get the security system up and running before connecting it to STARGATE. This will reduce the likelihood of problems and make troubleshooting much easier. [. . . ] Turn partitions chime mode ON This command turns on the chime mode for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Turn partitions chime mode OFF This command turns off the chime mode for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Toggle partitions instant mode This command toggles the "instant" mode for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Sound partitions Fire Panic This command sounds the "fire panic" alarm for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Sound partitions Medical Panic This command sounds the "medical panic" alarm for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Sound partitions Police Panic This command sounds the "police panic" alarm for the partition(s) specified. There will be separate check boxes on the screen for each partition in your system. Load user_VAR with User Number This command loads the most recent User Number entered into the user_VAR. There will be separate check boxes on the screen for each partition in your system. You can select any or all of the partitions. SECURITY SYSTEM CONDITIONS The following security system conditions can be used as IF - SECURITY conditions anywhere in your schedule. Transition Activated At the start of every schedule pass, STARGATE will process the information the GE/CADDX security panel has sent. Any changes to partitions or zones will cause an internal "transition" state to be set for that pass through the schedule, the "transition" state will be cleared at the end of the schedule pass. When the "Transition Activated" checkbox is selected, the IF condition will be TRUE when the condition goes active. When not selected, the IF condition will be TRUE when the condition is active. This is best explained in an example: EVENT: Partition Armed If SEC: Partition ARMED[Partion 1] TRANSITION Then LCD: Red LED ON [KP:ALL] End In the above example the LCD Keypads Red LED will be turned ON at the time the security panel becomes armed. EVENT: Security Lights If SEC: Partition ARMED[Partion 1] and Sunset SMTWTFS Then X10: F-1 Front Porch Lt ON End In this example the Front Porch light will turn ON if the security panel IS armed (as opposed to becomes armed) and the time is Sunset. Note: if "Transition Activated" was used, the Security Lights event would trigger only if the security panel became armed exactly at Sunset. User Number Events can be created based on the last user to arm or disarm the Caddx panel. [. . . ] Zone is not faulted This condition is true if the specified zone is not currently faulted. Zone is bypassed This condition is true if the specified zone is currently bypassed. Zone is not bypassed This condition is true if the specified zone is not currently bypassed. SECURITY SYSTEM CONDITIONS (Cont'd) Zone is in trouble condition This condition is true if the specified zone is currently in a "trouble" condition. Zone is not in trouble condition This condition is true if the specified zone is not currently in a "trouble" condition. [. . . ]